(a)On and after the date on which the performance test required to be conducted by § 60.8 is completed, no owner or operator of a glass melting furnace subject to the provisions of this subpart shall cause to be discharged into the atmosphere—
(1)From any glass melting furnace fired exclusively with either a gaseous fuel or a liquid fuel, particulate matter at emission rates exceeding those specified in table CC-1, Column 2 and Column 3, respectively, or
(2)From any glass melting furnace, fired simultaneously with gaseous and liquid fuels, particulate matter at emission rates exceeding STD as specified by the following equation: STD = X [1.3(Y) + (Z)] Where: STD = Particulate matter emission limit, g of particulate/kg (lb of particulate/ton) of glass produced. X = Emission rate specified in table CC-1 for furnaces fired with gaseous fuel (Column 2). Y = Decimal fraction of liquid fuel heating value to total (gaseous and liquid) fuel heating value fired in the glass melting furnaces as determined in § 60.296(b). (joules/joules). Z = (1-Y).
(b)Conversion of a glass melting furnace to the use of liquid fuel is not considered a modification for the purposes of § 60.14.
(c)Rebricking and the cost of rebricking is not considered a reconstruction for the purposes of § 60.15.
(d)An owner or operator of an experimental furnace is not subject to the requirements of this section.
(e)During routine maintenance of add-on pollution controls, an owner or operator of a glass melting furnace subject to the provisions of paragraph
(a)of this section is exempt from the provisions of paragraph
(a)of this section if:
(1)Routine maintenance in each calendar year does not exceed 6 days;
(2)Routine maintenance is conducted in a manner consistent with good air pollution control practices for minimizing emissions; and
(3)A report is submitted to the Administrator 10 days before the start of the routine maintenance (if 10 days cannot be provided, the report must be submitted as soon as practicable) and the report contains an explanation of the schedule of the maintenance. Table CC-1—Emission Rates [g of particulate/kg of glass produced] Col. 1—Glass manufacturing plant industry segment Col. 2—Furnace fired with gaseous fuel Col. 3—Furnace fired with liquid fuel Container glass0.10.13 Pressed and blown glass
(a)Borosilicate Recipes0.50.65
(b)Soda-Lime and Lead Recipes0.10.13
(c)Other-Than Borosilicate, Soda-Lime, and Lead Recipes (including opal, fluoride, and other recipes)0.250.325 Wool fiberglass0.250.325 Flat glass0.2250.225 [45 FR 66751, Oct. 7, 1980, as amended at 49 FR 41035, Oct. 19, 1984; 54 FR 6674, Feb. 14, 1989; 65 FR 61759, Oct. 17, 2000]
Connections3 cite this
Cited by 3 sections · top 2
Citation graph
cites case law
§ 60.292
Standards for particulate matter.
Fed. Reg.×3
Cites 0Cited by 3 across 1 source
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.